Every energy code you can choose under Energy Code Used, with the compliance paths it offers in the Rating System list.

On this page

Certifications and programs (LEED, NGBS, Enterprise Green Communities, Living Building Challenge, ILFI Zero Carbon, ILFI Zero Energy, Net Zero Energy Certifications, C-PACE and 179D) can be chosen with any code. A code marked superseded has a newer edition in effect, and stays available for projects permitted under it.

ASHRAE Standard 90.1

Energy codeWhereCompliance paths
ASHRAE Standard 90.1-2007National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2010National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2013National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2016National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2019National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2022National model codePerformance Rating Method
Energy Cost Budget Method
ASHRAE Standard 90.1-2025National model codePerformance Rating Method
Energy Cost Budget Method

International Energy Conservation Code (IECC)

Energy codeWhereCompliance paths
IECC - 2006National model codeTotal Building Performance
Total Building Performance limit: 100% of the standard reference design's energy cost
IECC - 2009National model codeTotal Building Performance
Total Building Performance limit: 100% of the standard reference design's energy cost
IECC - 2012National model codeTotal Building Performance
Total Building Performance limit: 85% of the standard reference design's energy cost
IECC - 2015National model codeTotal Building Performance
Total Building Performance limit: 85% of the standard reference design's energy cost
IECC - 2018National model codeTotal Building Performance
Total Building Performance limit: 85% of the standard reference design's energy cost
IECC - 2021National model codeTotal Building Performance
Total Building Performance limit: 85% of the standard reference design's energy cost

International Green Construction Code (IgCC)

Energy codeWhereCompliance paths
IgCC-2012 (ASHRAE 90.1-2010)National model codePerformance Option (zEPI)
IgCC-2015 (ASHRAE 90.1-2013)National model codePerformance Option (zEPI)
IgCC-2018 (ASHRAE 90.1-2016)National model codePerformance Option (zEPI)
IgCC-2021 (ASHRAE 90.1-2019)National model codePerformance Option (zEPI)

State and city energy codes

Energy codeWhereCompliance paths
2017 DC Energy CodeDistrict of ColumbiaPerformance Rating Method
MA Energy Code - 2020 supersededMassachusetts2020 MA Energy Code - Pathway 1a
2020 MA Energy Code - Pathway 1b
Performance Rating Method
MA Energy Code - 2021Massachusetts2021 MA Energy Code - Targeted Performance
2021 MA Energy Code - Relative Performance
2022 Chicago Energy Code (ASHRAE 90.1-2019)Chicago, ILPerformance Rating Method
Energy Cost Budget Method
Total Building Performance
Total Building Performance limit: 80% of the standard reference design's energy cost
2024 Minnesota Energy Code (ASHRAE 90.1-2019)MinnesotaPerformance Rating Method
Energy Cost Budget Method
2020 New York State Energy Code, outside NYC (ASHRAE 90.1-2016) supersededNew York StatePerformance Rating Method
Energy Cost Budget Method
Total Building Performance
Total Building Performance limit: 85% of the standard reference design's energy cost
2020 New York City Energy Code (ASHRAE 90.1-2016) supersededNew York CityPerformance Rating Method
Energy Cost Budget Method
2025 New York City Energy Code (ASHRAE 90.1-2022)New York CityPerformance Rating Method
Energy Cost Budget Method
2021 Oregon Energy Code (ASHRAE 90.1-2019) supersededOregonPerformance Rating Method
Energy Cost Budget Method
2025 Oregon Energy Code (ASHRAE 90.1-2022)OregonPerformance Rating Method
Energy Cost Budget Method

Notes

  • IECC and ASHRAE 90.1. An IECC edition allows the ASHRAE 90.1 edition of its time instead of its own requirements (IECC 2009: 90.1-2007; 2012: 90.1-2010; 2015: 90.1-2013; 2018: 90.1-2016; 2021: 90.1-2019). To use that alternative, choose the 90.1 edition as the Energy Code Used.
  • ASHRAE 90.1-2025 has no building performance factors in InverseHub yet.
  • IECC 2006 has no standard reference design tables in InverseHub yet, so Fill Baseline leaves envelope, fenestration and lighting for you.
  • State and city codes that change some baseline rules show a reminder in Fill Baseline to check the values against the code’s text.

Missing a code you work with? Email support@inversenergy.com.